I. Osnovna provjera točnosti
1. Repeatability Test: Measure 20 times consecutively using a standard part. The repeatability accuracy should be ≤0.8μm (≤0.3μm for high-precision models). If the standard deviation is >1,2 μm, potrebna je kalibracija.
2. Systematic Error Detection: Measure standard parts of different sizes (e.g., 10mm, 50mm, 100mm). If the deviation is consistently >±2,5μm, potrebna je kompenzacija.
3. Provjera geometrijske točnosti:
Guide rail straightness: Error per meter >2μm
Worktable flatness: Full stroke error >3μm
Three-axis perpendicularity: Angular error >5 lučnih sekundi.
II. Procjena sustava sonde
Calibration ball diameter consistency: If the measurement difference in different directions by the same probe is >0.8μm or the roundness error is >0,5 μm, potrebna je ponovna kalibracija.
Multi-probe consistency: If the deviation of each probe measuring the same dimension is >2μm, odnos sonde treba kalibrirati.
III. Kontrola temperature i održavanja
Temperaturna stabilnost: Promjene temperature okoline > ±0,5 stupnjeva mogu utjecati na točnost.
Dnevno održavanje: Redovito čistite i pregledavajte istrošenost rupa za pozicioniranje (poput povećanja veličine ili deformacije); popravak ili zamjena su potrebni u teškim slučajevima.


